WiseAir – Room Cooling CRAC
Atom's leading room air conditioning solutions are equipped with inverter compressors and intelligent control systems to provide high-precision, high-reliability IT environments.
TALK TO MMC
Plan your next step with our team
Share your requirements, location and timeline. We'll help you define a suitable solution and delivery scope.
[email protected]
Room Cooling System
A wide range of cooling systems and airflow options are available to meet the varied needs of any data center. Efficiency can be further improved with hot and cold aisle containment and free cooling solutions.
Product Features & Technical Specifications
Atom offers various types of cooling systems, including DX air-cooled, DX water-cooled, and chilled water-cooled options. Additionally, we provide support for hybrid dual-fluid systems, adapted precisely to deliver individual solutions tailored to your project requirements.
WiseAir – Product Configuration
Configuration
- Highly reliable scroll compressor.
- Industry leading brands EC / AC fan
- Intelligent industry-leading controller with color touch screen. Supports BMS integration, teamwork and master/slave working policy.
- A large area of high-efficiency heat exchanger.
- Industry-leading brands thermostatic expansion valve/electronic expansion valve.
- A large area air filtration system closed to heat exchanger
- Electrode humidifier
- Modular design of cabinet can easily achieve secondary disassembly
Airflow · Cooling types · Options
Efficiency & Reliability
- Top components from leading brands and unique design assure high reliability of products.
- All types of cooling systems and airflow options, it is fully compatible with hot and cold aisle systems to provide an efficient cooling environment.
- Inverter compressor and EC fan with intelligent control system ensure precise temperature control.
- Indirect Free Cooling with Refrigerant Pump Technology for minimizing the energy consumption of the cooling system.

Green Efficiency Free Cool
- Indirect free cooling with refrigerant pump technology, PUE low to 1.2.
- No water consumption during free cooling mode.
- No water loop introduced into server room, no flooding concern.
- Indirect type No dust, moisture concern.
- Automatic mode switching, and no complex maintenance and service.

Intelligent Control System
- Industry leading smart control system, with insightful sensor data and intelligent control logics.
- All digital control to major components, maintaining optimum working status, and flexible adjustment per onsite working conditions.
- 1000+ alarm records, and 7days history pressure curve records, 7days history temperature curve records.
- Smart monitoring protocols: Web/SNMP/Modbus/Bac-net/Email/Dry contact/IPV6.
- Teamwork function including Master/Slave Working mode, Master Control mode and Force Working mode.
- Built in web server support visit with web-browser from computers and mobile devices, can view, control unit through web.

Flexible Fans Sinking Design
Available in three widths and three depths, air flow front / side discharge, and adjustable vent air baffle. Allows us to provide a customized fit for different data center configurations. Suitable for racks from any manufacturers, you can also easily expand or reconfigure your existing infrastructure without disrupting the existing setup.

All Types of Air Conduction Systems

Down Flow

Supply Flow

Up-front Flow

Up Flow
Key Components

Inverter Compressor
- Stable temperature control per heating load by adjusting compressor output.
- Reducing energy cost and improve compressor working life.
- Green refrigerant R410A no ODP effect.
- Capacity adjustable 30%-100%.

EC Fans
- Best in class design and reliability.
- Highest efficiency EC Fan system.
- Speed adjustable 0%-100%.
- Direct drive system no belts easier replacement and service.
- Higher external static flexible for special application.

Electronic Expansion Valve
- Automatically modulating refrigerant flow per system requirement.
- Better COP performance during low temperature season comparing TEV system.
- Better refrigerant flow feeding during compressor startup, to reach higher reliability of compressor working.

W Shape Airflow Distribution
- W shape evaporator coil, optimized even airflow distribution and better energy efficiency performance.
- Modular design, easy to expand flexibly according to your individual needs.
- Air filters directly covering the coils, minimize wind resistance and increase efficiency.
Technical data
Technical data from the ATTOM product brochure.
DX Air Cooled · 5.5-27.5 kW
| Downflow unit | B-0052A | B-0073A | B-0120A | B-0173A | B-0200A | B-0250A |
|---|---|---|---|---|---|---|
| Upflow unit | W-0054A | W-0074A | W-0124A | W-0174A | W-0204A | W-0254A |
| Cooling capacity (kW) | 5.9 | 8.2 | 12.5 | 17.5 | 21.2 | 27.5 |
| Sensible cooling (kW) | 5.2 | 6.8 | 10.4 | 15.8 | 18.6 | 25.1 |
| SHR (%) | 84.6 | 86.7 | 80.4 | 90.6 | 90.1 | 90.1 |
| Air volume (m³/h) | 2000 | 2250 | 2850 | 5000 | 6200 | 6700 |
| Fan type | AC / EC | AC / EC | AC / EC | AC / EC | AC / EC | AC / EC |
DX Air Cooled · 32.5-122.9 kW
| Model | — |
|---|---|
| See brochure | Add data |
DX Water Cooled
| Model | — |
|---|---|
| See brochure | Add data |
Chilled Water · 30-110
| Model | — |
|---|---|
| See brochure | Add data |
Chilled Water · 120-200
| Model | — |
|---|---|
| See brochure | Add data |
ATTOM data centers at mission-critical sites
Deployments of ATTOM, the data center brand MMC supplies, installs and supports in Pakistan. Case studies published by ATTOM.
AgileMod containment data center for CPPA-G
A dual-row, six-rack cold-aisle containment system with overhead cable trays and multi-factor access control for Pakistan's Central Power Purchasing Agency.
Read ATTOM case study
AgileCub data center for the Central Reserve Bank
A high-security container data center with bullet-resistant protection, access control and redundant power, delivered on a shorter timeline with efficient cooling.
Read ATTOM case study
Tier III container data center for Mindanao State University
A containerised data center with redundant power, precision cooling and real-time monitoring, part of MSU's move to a smart campus.
Read ATTOM case studyRESOURCES

Planning room cooling for your data center?
Talk to our cooling experts to choose the right capacity and configuration for your site.

Get WiseAir from MMC
Tell us about your site and load. We will recommend the right configuration and send a detailed quote.
- Authorised ATTOM partnerGenuine ATTOM products and warranty, supplied locally.
- Site survey & designOur engineers size the cooling capacity for your heat load and space.
- Installation & commissioningDelivery, installation and commissioning by MMC’s data center team.
- Ongoing supportMaintenance and support from our Karachi head office.
Plan with MMC
Server room air conditioner selection
Choose a server room air conditioner for the room’s equipment loads and operating pattern. Review WiseAir Room Cooling alongside airflow management and monitoring.
Define the requirement
Provide equipment heat loads, room dimensions, environmental limits and any existing cooling. Identify growth, maintenance and resilience expectations.
Compare the delivery scope
Review air distribution, controls and fault alarms with the equipment layout. Confirm the capacity and configuration in the current technical quotation.