MMC PAKISTAN · WiseAir – Room Cooling CRAC

WiseAir – Room Cooling CRAC

Atom's leading room air conditioning solutions are equipped with inverter compressors and intelligent control systems to provide high-precision, high-reliability IT environments.

TALK TO MMC

Plan your next step with our team

Share your requirements, location and timeline. We'll help you define a suitable solution and delivery scope.

[email protected]
Talk to our team

WiseAir enquiry. We reply within one business day.

Read our Privacy policy before submitting.

Or call +92 311 1555053

5kW – 120kWDX air cooled
30kW – 120kWDX water cooled
30kW – 200kWChilled water
PUE 1.2Indirect free cooling
Room Cooling System

Room Cooling System

A wide range of cooling systems and airflow options are available to meet the varied needs of any data center. Efficiency can be further improved with hot and cold aisle containment and free cooling solutions.

Suited for
Finance & BankingEducationMedicalGovernmentEnterpriseTelecom

Product Features & Technical Specifications

Atom offers various types of cooling systems, including DX air-cooled, DX water-cooled, and chilled water-cooled options. Additionally, we provide support for hybrid dual-fluid systems, adapted precisely to deliver individual solutions tailored to your project requirements.

WiseAir – Product Configuration

Configuration

  1. Highly reliable scroll compressor.
  2. Industry leading brands EC / AC fan
  3. Intelligent industry-leading controller with color touch screen. Supports BMS integration, teamwork and master/slave working policy.
  4. A large area of high-efficiency heat exchanger.
  5. Industry-leading brands thermostatic expansion valve/electronic expansion valve.
  6. A large area air filtration system closed to heat exchanger
  7. Electrode humidifier
  8. Modular design of cabinet can easily achieve secondary disassembly

Airflow · Cooling types · Options

DownflowUpflowAir-cooledWater-cooledChilled waterLong Piping KitLow-temperature KitWater Leaking KitRS485 / SNMP Network Monitoring CardAutomatic Phase Switching ModuleLightning Protection ModuleLarge Color DisplayHigh-power Electric Heating SystemRemote Temperature and Humidity sensorUltra-quiet Air-cooled Outdoor Condenser

Efficiency & Reliability

  • Top components from leading brands and unique design assure high reliability of products.
  • All types of cooling systems and airflow options, it is fully compatible with hot and cold aisle systems to provide an efficient cooling environment.
  • Inverter compressor and EC fan with intelligent control system ensure precise temperature control.
  • Indirect Free Cooling with Refrigerant Pump Technology for minimizing the energy consumption of the cooling system.
Efficiency & Reliability

Green Efficiency Free Cool

  • Indirect free cooling with refrigerant pump technology, PUE low to 1.2.
  • No water consumption during free cooling mode.
  • No water loop introduced into server room, no flooding concern.
  • Indirect type No dust, moisture concern.
  • Automatic mode switching, and no complex maintenance and service.
Green Efficiency Free Cool

Intelligent Control System

  • Industry leading smart control system, with insightful sensor data and intelligent control logics.
  • All digital control to major components, maintaining optimum working status, and flexible adjustment per onsite working conditions.
  • 1000+ alarm records, and 7days history pressure curve records, 7days history temperature curve records.
  • Smart monitoring protocols: Web/SNMP/Modbus/Bac-net/Email/Dry contact/IPV6.
  • Teamwork function including Master/Slave Working mode, Master Control mode and Force Working mode.
  • Built in web server support visit with web-browser from computers and mobile devices, can view, control unit through web.
Intelligent Control System

Flexible Fans Sinking Design

Available in three widths and three depths, air flow front / side discharge, and adjustable vent air baffle. Allows us to provide a customized fit for different data center configurations. Suitable for racks from any manufacturers, you can also easily expand or reconfigure your existing infrastructure without disrupting the existing setup.

Flexible Fans Sinking Design

All Types of Air Conduction Systems

Down Flow

Down Flow

Supply Flow

Supply Flow

Up-front Flow

Up-front Flow

Up Flow

Up Flow

Key Components

Inverter Compressor

Inverter Compressor

  • Stable temperature control per heating load by adjusting compressor output.
  • Reducing energy cost and improve compressor working life.
  • Green refrigerant R410A no ODP effect.
  • Capacity adjustable 30%-100%.
EC Fans

EC Fans

  • Best in class design and reliability.
  • Highest efficiency EC Fan system.
  • Speed adjustable 0%-100%.
  • Direct drive system no belts easier replacement and service.
  • Higher external static flexible for special application.
Electronic Expansion Valve

Electronic Expansion Valve

  • Automatically modulating refrigerant flow per system requirement.
  • Better COP performance during low temperature season comparing TEV system.
  • Better refrigerant flow feeding during compressor startup, to reach higher reliability of compressor working.
W Shape Airflow Distribution

W Shape Airflow Distribution

  • W shape evaporator coil, optimized even airflow distribution and better energy efficiency performance.
  • Modular design, easy to expand flexibly according to your individual needs.
  • Air filters directly covering the coils, minimize wind resistance and increase efficiency.

Technical data

Technical data from the ATTOM product brochure.

DX Air Cooled · 5.5-27.5 kW

Downflow unitB-0052AB-0073AB-0120AB-0173AB-0200AB-0250A
Upflow unitW-0054AW-0074AW-0124AW-0174AW-0204AW-0254A
Cooling capacity (kW)5.98.212.517.521.227.5
Sensible cooling (kW)5.26.810.415.818.625.1
SHR (%)84.686.780.490.690.190.1
Air volume (m³/h)200022502850500062006700
Fan typeAC / ECAC / ECAC / ECAC / ECAC / ECAC / EC

DX Air Cooled · 32.5-122.9 kW

Model—
See brochureAdd data

DX Water Cooled

Model—
See brochureAdd data

Chilled Water · 30-110

Model—
See brochureAdd data

Chilled Water · 120-200

Model—
See brochureAdd data

ATTOM data centers at mission-critical sites

Deployments of ATTOM, the data center brand MMC supplies, installs and supports in Pakistan. Case studies published by ATTOM.

AgileMod containment data center for CPPA-G
Energy · Islamabad, Pakistan

AgileMod containment data center for CPPA-G

A dual-row, six-rack cold-aisle containment system with overhead cable trays and multi-factor access control for Pakistan's Central Power Purchasing Agency.

Read ATTOM case study
AgileCub data center for the Central Reserve Bank
Finance · El Salvador

AgileCub data center for the Central Reserve Bank

A high-security container data center with bullet-resistant protection, access control and redundant power, delivered on a shorter timeline with efficient cooling.

Read ATTOM case study
Tier III container data center for Mindanao State University
Education · Philippines

Tier III container data center for Mindanao State University

A containerised data center with redundant power, precision cooling and real-time monitoring, part of MSU's move to a smart campus.

Read ATTOM case study

RESOURCES

Planning room cooling for your data center?

Talk to our cooling experts to choose the right capacity and configuration for your site.

Planning room cooling for your data center?

Get WiseAir from MMC

Tell us about your site and load. We will recommend the right configuration and send a detailed quote.

  • Authorised ATTOM partnerGenuine ATTOM products and warranty, supplied locally.
  • Site survey & designOur engineers size the cooling capacity for your heat load and space.
  • Installation & commissioningDelivery, installation and commissioning by MMC’s data center team.
  • Ongoing supportMaintenance and support from our Karachi head office.
Talk to our team

WiseAir enquiry. We reply within one business day.

Read our Privacy policy before submitting.

Or call +92 311 1555053

Plan with MMC

Server room air conditioner selection

Choose a server room air conditioner for the room’s equipment loads and operating pattern. Review WiseAir Room Cooling alongside airflow management and monitoring.

Define the requirement

Provide equipment heat loads, room dimensions, environmental limits and any existing cooling. Identify growth, maintenance and resilience expectations.

Compare the delivery scope

Review air distribution, controls and fault alarms with the equipment layout. Confirm the capacity and configuration in the current technical quotation.

Our reach

Countries we serve

  • Pakistan flagPakistan
  • USA flagUSA
  • Australia flagAustralia
  • Belgium flagBelgium
  • Paraguay flagParaguay
  • Denmark flagDenmark
  • UK flagUK
  • Afghanistan flagAfghanistan
  • Philippines flagPhilippines
  • Turkey flagTurkey
  • Thailand flagThailand
  • Canada flagCanada
  • Sweden flagSweden
  • Singapore flagSingapore
  • Colombia flagColombia
  • UAE flagUAE
  • New Zealand flagNew Zealand
  • Kyrgyzstan flagKyrgyzstan
  • France flagFrance
  • Switzerland flagSwitzerland
  • Tanzania flagTanzania
  • Uganda flagUganda
  • Tajikistan flagTajikistan
  • China flagChina
  • Italy flagItaly
  • Finland flagFinland
  • Qatar flagQatar
  • Zimbabwe flagZimbabwe
  • Saudi Arabia flagSaudi Arabia